工程概况
期设计2×600MW亚界汽轮发电机组
工程质情况:工程持力层采③圆砾层做持力层③圆砾层顶般埋深30m ~45m般厚度65m ~95m④细中砂层层顶埋深般100m ~130m般厚度50m~70m⑤圆砾层分布④层层顶般埋深150m ~180m⑥粘土(残积土)褐色稍湿坚硬覆凝灰岩厚度68m
二 编制
火电施工质量检验评定标准
电力建设施工验收技术规范
建筑施工计算手册
时土方开挖图纸
三 降水方案选择
该项目处伊敏河畔属砂砾质结构渗透系数150m天容水量受降水影响水位波动变幅12m 枯水期6m左右工程部分建筑物埋深6m处界状态丰水期法施工工程采取措施:采明沟集水井方式进行作业层表面水降水枯水期柱基础底脚施工完回填完防止丰水期淹没减少降水施工降水费基础埋深超6m采局部井点降水
工程厂房基础底标高50m须采井点降水循环水泵坑汽轮机基础底标高75m采轻型井点降水基础面基底长度约50m宽度约36m基础埋深见施工图面持力层圆砾层井点降水避免量涌水泥翻浆砂砾层中开挖基坑时防止流砂现象发生渗流改善土性质基底土质更加密实结合工程基础施工枯水期期间周期较长特点采轻型井点降水法建筑物环状布置进行工降水时基坑二角设集水箱配合4台QY35型潜水泵排明水方法
四 井点降水相关计算
1井点埋设深度
H≥H1+h+iL+l
式中 H——井点埋设深度(m)
H1——井点埋设面基坑底面距离(m) 取30m
h—— 基坑中央深挖掘面降水曲线点安全距离(m)取10m
L—— 井点中心基坑中心短边距离(m) 取27
i—— 降水曲线坡度 取110
l—— 滤长度(m)取12
H≥30+10+27×110+1279m 取8m
2涌水量计算
(2HS)S
LgRLgXO
Q1366K
Q——井点系统总涌水量(m3d)
K——渗透系数(md)取150
H——含水层厚度(m)计算暂取11m
R——抽水影响半径(m)计算取91
S——水位降低值(m)取12水位取68m
XO——基坑设想半径(m) 计算取24
工程压非完整井计算
(2×1112)×12
Lg91Lg24
Q1366×150
8818m3d
3计算井点数量间距
单井出水量q65πd l×3 K
65×314×005×12×3 150
65 m3d
需井点数量
n11Qq149根
基坑四角处机械入口处井点应加密采井点数量149+32181根
井点间距均D2×86(1811)096m 取10m机械入口处井点泵1泵6井点间距08m
布置时机械挖土开行路线宜布置成端部开口(留6根井点距离)实际需井点数量
n2×661+4008 5177根
4校核水位降低数值
h 102 8818(1366×150)× (Lg 91 Lg24)
87m
实际降低水位S108713m
值需降低水位数值12m相符布置行
5结
根标书水位情况目前水位厂房零米 –60米左右现场测量实际情况685m工程井点深度80 m(50m 处埋)间完全保障降水求降水井点布置见汽机房基础降水井点面布置图轻型井点埋深剖面图
五 降水设备
1工程设轻型射流泵(JSJ60)6台工作水流45m3h离心泵(3BL9)6套电动机(JO2422)6台孔4套QY35型潜水泵4台
2射流泵轻型井点降水井点167根总(中导流总120m)长度320m配循环水箱(1200×1200×1500×4mm)2
3井点:工程井点采直径48mm钢长度68m端配井点径滤尖滤长度12m滤壁钻呈梅花状直径φ12滤孔滤孔面积般滤表面积1520滤壁处包两层滤网层采网眼3050孔cm2尼龙丝布细滤网外层采网眼310孔cm2尼龙丝布粗滤网井点端弯总相连
4连接集水总工程连接采φ48高压软长度12m集水总采直径100mm钢分节连接节长度6m间隔0810m设连接接头总间法兰连接
5排水长度现场集水箱水道实际距离定径少选φ100
六 施工工期
井点降水开工时间2005年4月20日2005年4月30日达降水效果进行基础土方二次开挖施工
七 井点施工方法
1施工流程
布置井点 井点总连接 试抽水 进入工作状态 基础结束回填完拔
2井点施工方法
(1)井点埋设
1)采直径70mm水进行孔水压力采离心泵循环抽送孔进应垂直插入土中作左右摆动加剧砂土松动孔旁挖排泥浆水沟深度应滤深度深05m便流泥井点孔壁间时粗砂灌实井点位砂滤水层中间井点面05m深度粘土填实防止漏气
2)井点埋设完毕应接通总抽水设备进行试抽水检查漏水漏气现象出水否正常淤塞现象异常情况应时进行修理
(2)井点
井点工作应保证连续断排水正常出水规律先先混清水水直较混出现清水混等情况应立检查纠正
(3)井点拆
构筑物竣工进行回填土方拆井点系统留孔洞砂土填塞
3施工点
工程基坑面积较采建筑物环状布置井点井点布置距坑壁距离1015m井点间距0810m充分利泵抽空力集水总标高量接水位线抽水水流方05仰坡度水泵轴心总齐渗透系数150 md井点埋置深度基坑深度少深5m拉土进出口处设置井点
降水设施完毕开始降水降水汽轮机基础底板四角中部钻设直径400mm水位观测孔5(深20m)观测孔设置设备基础空白位置降水程中时观测水位进行记录发现水位异常时汇报降水程中水泵设备设专职员昼夜进行值班观测井点降水情况泵运行情况渗水量满足水泵运行时时更换水泵水位降设计基层05m进行土方施工
八 质量标准质量保证措施
1 质量标准
序号
检查项目
允许偏差
检查方法
1
滤器骨架孔隙率()
≥15
钢尺检查
2
滤料规格D50砂(d50)石(d20)土料含水层倍数
6~8
取土样
做筛分试验
3
井插入深度(mm)
≤200
水准仪
4
滤砂砾料填灌()
≤5
检查回填料量
5
井点真空度(kPa)
>60
真空度表
6
井间距(mm)
≤150
钢尺检查
7
抽排水含砂量(体积)
<110000
取水样做试验
8
井垂直度()
1
插时目测
9
降水深度
符合设计求
稳定24h
2质量保证措施
(1)坐标高程控制点厂区基准点引测检查验收合格进行土方开挖降水施工
(2)土方开挖前石灰划出开挖线确保土方开挖尺寸正确基坑开挖尺寸标高符合质量标准
(3)保证达效降水机械型号功率须达方案求现场配备泵
(4)施工区域设降水观察孔掌握解降水情况保证降水效果
(5)井点降水设备正常工作应设置专24时间隔值班防出现异常应时修复
(6)工程建筑物设置沉降观测点开始降水时应缓慢进行防止降水速度快影响原厂房基发生均匀沉降时观察原厂房沉降情况控制降水速度
(7)基坑范围较渗透系数宜基坑中部设置时井点系统进行辅助降水井点环封闭时机械挖土开行路线入口部位基坑外侧延长20m作保护段确保降水效果
九 危险点分析
1 电源线老化漏电伤
预防措施:根水泵电机电流量配置相应电源线做闸机漏电保护器动作灵活交接班时漏电保护器进行试动作防止长时间运行失灵
2 塌方
预防措施:土方施工求坡度放坡设置专巡视边坡稳定性防止土方坍塌事发生
3 机械伤害
预防措施:挖土工程交叉施工严禁机械挖土范围进行工降水施工防止机械伤害
4 高处坠落
预防措施:基坑四周设置红白相间警示栏杆栏杆距基坑1m防止车辆员坠入坑
十安全生产文明施工措施
1进入施工现场作业员必须正确佩戴安全帽穿戴劳动防护品
2交叉作业应设专监护防护措施否严禁施工免发生物体击碰撞事
3夜间施工安全明必须充足
4文明施工责区划分明确死角责落实设明显标记便检查监督
5施工机械设备完清洁安全操作规程齐全操作员持证岗熟悉机械性工作条件
6施工现场施工程中出现 种坑沟孔洞施工单位应根实际情况设置标准行安全沟道盖板围栏档脚板警告标志
7拉电源时严禁电线直接勾挂闸刀直接插入插座必须插头连接
8施工单位应常组织施工员进行安全文明施工学位施工员掌握安全文明施工知识断提高安全文明施工意识做安全生产文明施工
9井点降水处湿工作状态电源安全装置须达三级保护求
十环保措施
1井点施工产生泥浆弃土应时清运运输时必须覆盖避免产生扬尘遗撒
2排出水应沉淀处理方排入专道
3施工现场应遵守现行国家标准建筑施工场界噪声限值GB12523规定噪声限值发现超标应时采取措施纠正